Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Rev. Fac. Nac. Salud Pública ; 39(2): e337052, mayo-ago. 2021. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1356750

RESUMO

Resumen Objetivo: Analizar la diferencia en la pérdida auditiva según el consumo de alcohol, en mujeres de entre 20 y 40 años de edad, en la comuna de Temuco, Chile. Metodología: Estudio de corte, donde se evaluaron 30 mujeres consumidoras y no consumidoras de alcohol, divididas en 3 grupos (G): G1 abstemias, G2 consumidoras de 40-59 y G3 consumidoras demás de 60g de alcohol diarios (15, 6 y 9 respectivamente), con un muestreo intencional, contactadas en centros comerciales. Se realizaron pruebas auditivas: audiometría, discriminación de la palabra y potenciales evocados auditivos de tronco cerebral. Resultados: El oído derecho presentó diferencias significativas en las frecuencias medias y discriminación de la palabra en G1 vs. G2 (p = 0,045 y 0,010, respectivamente). El oído izquierdo mostró diferencias significativas en las frecuencias agudas en G1 vs. G3, en las latencias interpeakde las ondas iii-v (tiempo en milisegundo transcurrido entre la onda iii y v posterior al estímulo) en G1 vs. G2 (p = 0,003) y G2 vs. G3 (p = 0,005) a 80 dB; en las latencias interpeaki-iiiy iii-v en G1 vs. G2 (p = 0,039) a 60 dB y en la discriminación de la palabra en G1 vs. G2 (p = 0,009) y G1 vs. G3 (p = 0,013). Conclusiones: En el grupo estudiado existe pérdida auditiva relacionada con un consumo diario a partir de los 40g de alcohol, siendo el oído más afectado el izquierdo, en las frecuencias medias y agudas, en la cóclea y el tronco cerebral.


Abstract Objective: To analyze the relationship between alcohol consumption and loss hearing in women between 20 and 40 years of age in Temuco city. Methodology: Cutting study. We evaluated 30 consuming and non alcoholic women divided into 3 groups (G): G1 abstemies, G2 consumers of 40-59 and G3 consumers of> 60 grams alcohol daily (15, 6 and 9 respectively), intentional sampling contacted in shopping centers. Auditory tests were performed: Audiometry, Discrimination of the Word and Auditory Evoked Potentials of the Brain Stem. Results: In the right ear, there were significant differences in medium frequencies and word discrimination between groups 1 versus 2 (p = 0.045 and 0.010, respectively). In left ear, there were significant differences in the high frequencies between groups 1 versus 3, interpeak latencies of iii-v waves (time elapsed between iii and v waves in millisecond after the stimulus) between groups 1 versus 2 (p = 0.003) and groups 2 versus 3 (p = 0.005) to 80 dB; in interpeak latencies i-iii and iii-vbetween groups 1 versus 2 (p = 0.039) at 60 dB and in word discrimination between groups 1 versus 2 (p = 0.009) and 1 versus 3 (p = 0.013). Conclusion: In the group studied there is hearing loss related to a daily consumption from the 40 grams of alcohol being the most affected ear the left in the medium and high frequencies and affecting to the cochlea and also brainstem.


Resumo Objetivo: O objetivo foi analisar a relação entre consumo de álcool e perda auditiva em mulheres entre 20 e 40 anos. Metodologia: Foi realizado um estudo transversal não experimental em que 30 consumidoras femininas e não o álcool foram divididas em 3 grupos: abstêmios G1, consumidores G2 de 40-59 gramas e consumidores G3> 60 gramas de álcool por dia. Testes auditivos foram realizados: audiometria, discriminação de palavras e potencial evocado auditivo de tronco encefálico. O teste não paramétrico de Mann-Whitney U foi utilizado para a análise estatística. Resultados: Na orelha direita, há diferenças significativas nas frequências médias e discriminação de palavras entre os grupos 1 e 2 (p = 0,045 e 0,010, respectivamente). Na orelha esquerda, há diferenças significativas nas freqüências agudas entre os grupos 1 versus 3, nas latências interpicos das ondas iii-v entre os grupos 1 versus 2 (p = 0,003) e os grupos 2 versus 3 (p = 0,005) a 80dB; nas latências interpicos i-iii e iii-v entre os grupos 1 versus 2 (p = 0,039) a 60 dB e na discriminação de palavras entre os grupos 1 versus 2 (p = 0,009) e 1 versus 3 (p = 0,013). Conclusões: Há uma perda auditiva relacionada ao consumo diário de 40 gramas de álcool, sendo que a orelha mais afetou a esquerda nas freqüências média e aguda, afetando a cóclea e o tronco cerebral.

2.
CoDAS ; 33(6): e20200192, 2021. tab
Artigo em Inglês, Português | LILACS | ID: biblio-1339728

RESUMO

RESUMO Objetivo Verificar o benefício obtido pela prescrição de ganho acústico baseada nos limiares audiométricos obtidos com tons puros (Warble) e com ruído de faixa estreita (NB). Método Amostra de 30 idosos, com idade igual ou superior a 60 anos, perda auditiva neurossensorial de grau moderado a severo simétrica bilateral de configuração descendente com limiares em 4kHz iguais ou inferiores a 70dBNA. Foram dois grupos. GTP (grupo tom puro): 15 idosos tiveram as próteses auditivas adaptadas com emprego dos limiares obtidos com tom puro e grupo GNB (grupo Narrowband): 15 idosos tiveram as próteses auditivas adaptadas por meio dos limiares obtidos com NB. Os procedimentos realizados antes da adaptação de próteses auditivas e após três meses de uso de amplificação foram: Escala COSI, IPRF (Índice Percentual de Reconhecimento de fala), Relação Sinal/Ruído e análise do tempo de uso do AASI. O Questionário Internacional de Aparelho de Amplificação Sonora Individual (QI-AASI) foi aplicado após três meses. Resultados Os idosos do grupo em que as próteses auditivas foram adaptadas com ganho prescrito com base nos limiares auditivos obtidos com o estímulo Narrow Band apresentaram melhor desempenho nos seguintes testes: IPRF à orelha direita, pontuação total do questionário QI-AASI, escala COSI e maior tempo de uso do AASI em comparação ao grupo GTP. Conclusão Observou-se maior benefício com o uso de próteses auditivas, pela pontuação total do questionário QI-AASI, escala COSI e maior tempo de uso do AASI, no grupo cuja prescrição do ganho acústico baseou-se nos limiares audiométricos obtidos com o Narrowband.


ABSTRACT Purpose To verify the benefit obtained by the prescription of acoustic gain based on the auditory thresholds obtained with pure tones modulated in frequency and with Narrow Band Noise. Methods The sample consisted of 30 elderly people, aged 60 years or over with moderate to severe descending sensorineural symmetrical hearing loss with thresholds at 4kHz equal to or less than 70dBHL. There were two groups. GTP (pure tone group): 15 elderly people had their hearing aids fitted through the auditory thresholds obtained with pure tone and the GNB group (narrow band group): 15 elderly people had their hearing aids fitted through the auditory thresholds obtained with NB. The procedures performed before the fitting of hearing aids and after three months of amplification use were: COSI, WRS (Word Recognition Score), Signal/Noise ratio. The International Outcome Inventory for Hearing Aids (IOI-HA) was applied only after three months of hearing aid fitting. Results The elderly people in the group in which the hearing aids were fitted with a prescribed gain based on the hearing thresholds obtained with the Narrow Band stimulus showed better performance in the following tests: WRS on the right ear, total score of the IOI-HA inventory, COSI and longer use of hearing aids compared to the GTP group. Conclusion There was a greater benefit with the use of hearing aids, due to the total score of the IOI-HA inventory, COSI scale and longer daily use time of hearing aids, in the group whose prescription of acoustic gain was based on the auditory thresholds obtained with narrow band.


Assuntos
Humanos , Idoso , Auxiliares de Audição , Perda Auditiva Neurossensorial , Audiometria de Tons Puros , Limiar Auditivo , Acústica , Prescrições
3.
Braz. j. otorhinolaryngol. (Impr.) ; 86(6): 687-695, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1142606

RESUMO

Abstract Introduction: The study of the threshold level of cortical auditory response in adults has been investigated in previous studies. Due to maturational issues, little is known about these responses in neonates. Technological advances with automatic analysis devices now allow investigation in specific populations. Thus, new studies are needed to establish the feasibility of using this auditory potential to identify the lowest levels of responses in children. Objective: Verify and compare latency and amplitude in 80 dBnNA and the minimum level of cortical auditory response in term and preterm neonates. Methods: A cross-sectional, comparative study involving 59 neonates, 35 full-term births and 24 preterm births, with positive results in the Neonatal Hearing Screening. The Hearlab system was used to investigate the P1i auditory potential with tone burst stimulus at frequencies of 500, 1000, 2000 and 4000 Hz. The minimum response level search ranged from 80 to 0 dBNA and was detected automatically. The results were compared between groups, evaluating the latency and amplitude in 80 dBNA and the minimum level of cortical auditory response. Results: The mean values obtained for the minimum level of cortical auditory response in term group were 26 ± 8.81; 26.14 ± 6.97; 29 ± 7.65 and 29.43 ± 7.04 dBNA and for preterm neonates of 31.96 ± 10.41; 34.13 ± 11.34; 33.64 ± 11.03 and 37.73 ± 11.92 dBNA, for the frequencies of 500, 1000, 2000 and 4000 Hz, respectively. There was a difference between groups for the latency of P1i at 4000 Hz and the minimum response levels at 500, 1000 and 4000 Hz, with higher values for preterm infants. Conclusion: It was possible to obtain latency and amplitude values at 80 dBnNA and the minimum level of cortical response in term and preterm newborns, with different results between groups, with higher values in those born preterm.


Resumo Introdução: A investigação do nível mínimo de resposta auditiva cortical tem sido alvo de diferentes estudos em adultos. Devido a questões de maturação, pouco se sabe sobre essas respostas em recém-nascidos. Com o avanço tecnológico, dispositivos de análise automática surgiram com o objetivo de retomar essa avaliação em populações específicas. Assim, novos estudos são necessários para verificar a viabilidade do uso desse potencial auditivo na obtenção de níveis mínimos de respostas na criança. Objetivo: Verificar e comparar latência e amplitude em 80 dBnNA e o nível mínimo de resposta auditiva cortical em recém-nascidos a termo e pré-termo. Método: Estudo transversal, comparativo, envolvendo 59 neonatos, 35 nascidos a termo e 24 pré-termos, com resultados positivos na triagem auditiva neonatal. O sistema Hearlab foi utilizado para investigar o potencial auditivo P1i com estímulo tone burst nas frequências de 500, 1000, 2000 e 4000 Hz. A busca do nível mínimo de resposta variou de 80 a 0 dBNA e foi detectado automaticamente. Os resultados foram comparados entre os grupos, avaliando a latência e amplitude em 80 dBNA e o nível mínimo de resposta auditiva cortical. Resultados: Os valores médios obtidos para o nível mínimo de resposta auditiva cortical no grupo nascido a termo foram 26 ± 8,81; 26,14 ± 6,97; 29 ± 7,65 e 29,43 ± 7,04 dBNA e para recém-nascidos pré-termos foram de 31,96 ± 10,41; 34,13 ± 11,34; 33,64 ± 11,03 e 37,73 ± 11,92 dBNA, para as frequências de 500, 1000, 2000 e 4000 Hz, respectivamente. Houve diferenc¸a entre os grupos para a latência de P1i em 4000 Hz e os níveis mínimos de resposta em 500, 1000 e 4000 Hz, com valores maiores em Pré-termos. Conclusão: Foi possível obter valores de latência e amplitude em 80 dBnNA e o nível mínimo de resposta cortical em recém-nascidos a termo e Pré-termos, com resultados diferentes entre osgrupos, com valores maiores em pré-termos.


Assuntos
Humanos , Recém-Nascido , Recém-Nascido Prematuro , Potenciais Evocados Auditivos , Estimulação Acústica , Estudos Transversais , Potenciais Evocados Auditivos do Tronco Encefálico , Audição
4.
Braz. j. otorhinolaryngol. (Impr.) ; 86(2): 149-156, March-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1132569

RESUMO

Abstract Introduction: Hearing acuity, central auditory processing and cognition contribute to the speech recognition difficulty experienced by older adults. Therefore, quantifying the contribution of these factors on speech recognition problem is important in order to formulate a holistic and effective rehabilitation. Objective: To examine the relative contributions of auditory functioning and cognition status to speech recognition in quiet and in noise. Methods: We measured speech recognition in quiet and in composite noise using the Malay Hearing in noise test on 72 native Malay speakers (60-82 years) older adults with normal to mild hearing loss. Auditory function included pure tone audiogram, gaps-in-noise, and dichotic digit tests. Cognitive function was assessed using the Malay Montreal cognitive assessment. Results: Linear regression analyses using backward elimination technique revealed that had the better ear four frequency average (0.5-4 kHz) (4FA), high frequency average and Malay Montreal cognitive assessment attributed to speech perception in quiet (total r2 = 0.499). On the other hand, high frequency average, Malay Montreal cognitive assessment and dichotic digit tests contributed significantly to speech recognition in noise (total r2 = 0.307). Whereas the better ear high frequency average primarily measured the speech recognition in quiet, the speech recognition in noise was mainly measured by cognitive function. Conclusions: These findings highlight the fact that besides hearing sensitivity, cognition plays an important role in speech recognition ability among older adults, especially in noisy environments. Therefore, in addition to hearing aids, rehabilitation, which trains cognition, may have a role in improving speech recognition in noise ability of older adults.


Resumo Introdução: A alteração da acuidade auditiva, do processamento auditivo central e da cognição são fatores que contribuem para a dificuldade de reconhecimento da fala em idosos. Portanto, quantificar a contribuição desses fatores no problema de reconhecimento da fala é importante para a formulação de uma reabilitação holística e efetiva. Objetivo: Examinar as contribuições relativas do funcionamento auditivo e do estado cognitivo para o reconhecimento da fala no silêncio e no ruído. Método: Nós medimos o reconhecimento de fala no silêncio e no ruído composto com o teste Malay hearing in noise test em 72 idosos malaios nativos falantes (60-82 anos) com audição normal a perda auditiva de grau leve. A avaliação da função auditiva incluiu audiograma de tons puros, teste gaps-in-noise e testes dicótico de dígitos. A função cognitiva foi avaliada pelo teste Malay Montreal cognitive assessment. Resultados: Análises de regressão linear com técnicas de eliminação backward na orelha melhor revelaram média de quatro frequências (0,5-4 kHz) (4AF), média de alta frequência e teste Malay Montreal cognitive assessment na orelha melhor, mensurada pela percepção da fala no silêncio (r2 total = 0,499). Por outro lado, a média de alta frequência, Malay Montreal cognitive assessment e o teste dicótico de dígitos contribuíram significativamente para o reconhecimento da fala no ruído (r2 total = 0,307). Enquanto a média de alta frequência da melhor orelha mediu principalmente o reconhecimento da fala no silêncio, o reconhecimento da fala no ruído foi mensurado principalmente pela função cognitiva. Conclusões: Esses achados destacam o fato de que, além da sensibilidade auditiva, a cognição desempenha um papel importante na capacidade de reconhecimento da fala em idosos, principalmente em ambientes ruidosos. Portanto, além de aparelhos auditivos, a reabilitação, que treina a cognição, pode ter um papel na melhoria da capacidade do reconhecimento da fala no ruído entre os idosos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Presbiacusia/fisiopatologia , Limiar Auditivo/fisiologia , Percepção da Fala/fisiologia , Cognição/fisiologia , Ruído , Presbiacusia/diagnóstico , Audiometria de Tons Puros , Teste do Limiar de Recepção da Fala , Estimulação Acústica/métodos , Testes Auditivos
5.
Braz J Otorhinolaryngol ; 86(6): 687-695, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31331871

RESUMO

INTRODUCTION: The study of the threshold level of cortical auditory response in adults has been investigated in previous studies. Due to maturational issues, little is known about these responses in neonates. Technological advances with automatic analysis devices now allow investigation in specific populations. Thus, new studies are needed to establish the feasibility of using this auditory potential to identify the lowest levels of responses in children. OBJECTIVE: Verify and compare latency and amplitude in 80dBnNA and the minimum level of cortical auditory response in term and preterm neonates. METHODS: A cross-sectional, comparative study involving 59 neonates, 35 full-term births and 24 preterm births, with positive results in the Neonatal Hearing Screening. The Hearlab system was used to investigate the P1i auditory potential with tone burst stimulus at frequencies of 500, 1000, 2000 and 4000Hz. The minimum response level search ranged from 80 to 0dBNA and was detected automatically. The results were compared between groups, evaluating the latency and amplitude in 80dBNA and the minimum level of cortical auditory response. RESULTS: The mean values obtained for the minimum level of cortical auditory response in term group were 26±8.81; 26.14±6.97; 29±7.65 and 29.43±7.04dBNA and for preterm neonates of 31.96±10.41; 34.13±11.34; 33.64±11.03 and 37.73±11.92dBNA, for the frequencies of 500, 1000, 2000 and 4000Hz, respectively. There was a difference between groups for the latency of P1i at 4000Hz and the minimum response levels at 500, 1000 and 4000Hz, with higher values for preterm infants. CONCLUSION: It was possible to obtain latency and amplitude values at 80dBnNA and the minimum level of cortical response in term and preterm newborns, with different results between groups, with higher values in those born preterm.


Assuntos
Potenciais Evocados Auditivos , Recém-Nascido Prematuro , Estimulação Acústica , Estudos Transversais , Potenciais Evocados Auditivos do Tronco Encefálico , Audição , Humanos , Recém-Nascido
6.
Braz J Otorhinolaryngol ; 86(2): 149-156, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30558985

RESUMO

INTRODUCTION: Hearing acuity, central auditory processing and cognition contribute to the speech recognition difficulty experienced by older adults. Therefore, quantifying the contribution of these factors on speech recognition problem is important in order to formulate a holistic and effective rehabilitation. OBJECTIVE: To examine the relative contributions of auditory functioning and cognition status to speech recognition in quiet and in noise. METHODS: We measured speech recognition in quiet and in composite noise using the Malay Hearing in noise test on 72 native Malay speakers (60-82 years) older adults with normal to mild hearing loss. Auditory function included pure tone audiogram, gaps-in-noise, and dichotic digit tests. Cognitive function was assessed using the Malay Montreal cognitive assessment. RESULTS: Linear regression analyses using backward elimination technique revealed that had the better ear four frequency average (0.5-4kHz) (4FA), high frequency average and Malay Montreal cognitive assessment attributed to speech perception in quiet (total r2=0.499). On the other hand, high frequency average, Malay Montreal cognitive assessment and dichotic digit tests contributed significantly to speech recognition in noise (total r2=0.307). Whereas the better ear high frequency average primarily measured the speech recognition in quiet, the speech recognition in noise was mainly measured by cognitive function. CONCLUSIONS: These findings highlight the fact that besides hearing sensitivity, cognition plays an important role in speech recognition ability among older adults, especially in noisy environments. Therefore, in addition to hearing aids, rehabilitation, which trains cognition, may have a role in improving speech recognition in noise ability of older adults.


Assuntos
Limiar Auditivo/fisiologia , Cognição/fisiologia , Ruído , Presbiacusia/fisiopatologia , Percepção da Fala/fisiologia , Estimulação Acústica/métodos , Idoso , Audiometria de Tons Puros , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Presbiacusia/diagnóstico , Teste do Limiar de Recepção da Fala
7.
CoDAS ; 31(3): e20180058, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001844

RESUMO

ABSTRACT Purpose This study aimed to evaluate the effects of complete external ear canal occlusion on hearing thresholds with aging. The goal was to decide which tuning fork is more appropriate to use for the contralateral occlusion test (COT), in individuals of different ages. Methods Forty-two normal hearing subjects between 21 and 67 years were divided into three age groups (20-30 years, 40-50 years, and 60-70 years). Participants underwent sound field audiometry tests with warble tones, with and without ear canal occlusion. Each ear was tested with the standard frequencies (250, 500, 1000, and 2000 Hz). The contralateral ear was suppressed by masking. Results Hearing thresholds showed an increase as the frequency increased from 20.85 dB (250 Hz, 20-30 years group) to 48 dB (2000 Hz, 60-70 years group). The threshold differences between occlusion and no occlusion conditions were statistically significant and increased ranging from 11.1 dB (250 Hz, 20-30 years group) to 32 dB (2000 Hz, 20-30 years group). We found statistically significant differences for the three age groups and for all evaluations except to 500 Hz difference and average difference. The mean hearing loss produced by occlusion at 500 Hz was approximately 19 dB. We found no statistically significant differences between right and left ears and gender for all measurements. Conclusion We conclude that the use of the 512 Hz tuning fork is the most suitable for COT, and its use may allow clinicians to distinguish mild from moderate unilateral conductive hearing loss.


RESUMO Objetivo O objetivo deste estudo foi avaliar o efeito da oclusão completa do canal auditivo externo nos limiares auditivos, em indivíduos de idades distintas, para apurar qual o diapasão mais adequado na realização do teste de oclusão contralateral (TOC). Método 42 indivíduos normo-ouvintes (21-67 anos) foram divididos em três grupos etários (20-30, 40-50 e 60-70 anos). Os participantes foram avaliados com testes de audiometria tonal liminar em campo livre, com e sem oclusão completa do canal auditivo externo. Cada ouvido foi testado para as frequências 250, 500, 1000 e 2000 Hz. No ouvido contralateral, foi realizado mascaramento, para evitar a ocorrência de audição contralateral. Resultados Verificou-se aumento dos limiares auditivos, diretamente proporcional ao aumento da frequência (desde 20.85 até 48 dB). A diferença nos limiares auditivos entre a condição de oclusão e de não oclusão foi estatisticamente significativa em todas as frequências e aumentou de forma diretamente proporcional com a frequência (desde 11.1 até 32 dB). Foram também encontradas diferenças estatisticamente significativas para os três grupos etários, em todos os parâmetros, exceto na diferença a 500 Hz e na diferença total média. A perda auditiva média resultante da oclusão aos 500 Hz foi de 19 dB. Não se encontraram diferenças estatisticamente significativas entre o ouvido direito e o esquerdo, e entre o gênero. Conclusão A utilização do diapasão de 512 Hz é a mais adequada para o TOC. A sua utilização pode permitir aos clínicos, em ambiente de consulta e de forma rápida, a distinção entre perda condutiva de grau leve a moderada.


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Adulto Jovem , Envelhecimento/fisiologia , Meato Acústico Externo/fisiologia , Perda Auditiva Condutiva/diagnóstico , Testes Auditivos/métodos , Audiometria de Tons Puros , Limiar Auditivo , Estudos Transversais , Perda Auditiva Condutiva/fisiopatologia , Pessoa de Meia-Idade
8.
Distúrb. comun ; 30(2): 376-384, jun. 2018. ilus, tab
Artigo em Português | LILACS | ID: biblio-911151

RESUMO

Introdução: A audição, sentido que nos permite receber a informação sonora, se apresenta como um dos facilitadores para uma interação social eficaz. Um déficit nessa função acarreta prejuízo no processo comunicativo, devendo ser diagnosticado e tratado precocemente. Atualmente dispomos de meios subjetivos e objetivos para avaliar o sistema auditivo. A audiometria tonal é a forma subjetiva mais aplicada para medir esse sentido. Entretanto, em populações impossibilitadas de responder subjetivamente, aplicam-se técnicas objetivas, como o Potencial Evocado Auditivo de Estado Estável. Ambos pesquisam respostas auditivas do sujeito sob teste, utilizando técnicas distintas. Objetivo: Avaliar adultos jovens, sem queixas auditivas, pesquisando a sensibilidade auditiva e, a partir de indicadores estatísticos, calcular as médias das diferenças das respostas obtidas nesses procedimentos, verificando se há correlação entre eles. Método: Pesquisa de respostas auditivas via Audiometria Tonal e Potencial Evocado Auditivo de Estado Estável, nas frequências de 500, 1000, 2000 e 4000 Hz, em 30 sujeitos normo-ouvintes. Resultados: Ao calcularmos a média das diferenças entre as frequências testadas nos dois procedimentos, elas variaram de 10,47 a 18,22, não havendo forte correlação em nenhuma delas, deixando dúvidas na frequência de 1000 Hz. Conclusão: Podemos dizer que as médias das diferenças entre os valores obtidos nos dois procedimentos foram razoavelmente elevadas, principalmente em 500 Hz e, em menor proporção, para 4 kHz. Os valores obtidos nos dois exames, embora não tenham apresentado forte correlação, apresentaram-se discretamente melhores para 500 Hz. Resultados de 1000 Hz não nos permitem afirmar, inclusive, se existe alguma correlação entre os testes.


Introduction: Hearing is the sense which allows us to receive auditory information; therefore it facilitates efficient social interaction. Any loss in this function damages the communicative process, so it must be diagnosed and treated as soon as possible. Nowadays, both objective and subjective hearing tests are available. Pure Tone Audiometry is the most widely used subjective way to evaluate this sense. However, for those who are unable to respond subjectively, we can try objective techniques like the Auditory Steady State Response. Both will search for patients' minimum hearing responses, applying different approaches. Objective: To evaluate normal-hearing young adults with no hearing complaints by analyzing their hearing sensibility and, based on statistical indicators, calculate the average of the differences between the results obtained in both procedures in order to verify the existence of correlation between them. Method: We studied the hearing responses from 30 normal-hearing subjects through Pure Tone Audiometry and Auditory Steady State Response at 500, 1000, 2000 and 4000 Hz. Results: When we calculated the average of the differences between the tested frequencies, they ranged from 10,47 to 18,22 with no strong correlation, except at 1000 Hz whose results were uncertain. Conclusion: We concluded that the average of the differences of hearing values obtained in Pure Tone Audiometry and Auditory Steady State Response were reasonably elevated mainly at 500 Hz, and at a lower level at 4000 Hz. Although the scores obtained in both tests had not shown strong correlation, they were slightly better at 500 Hz. The results for 1000 Hz are inconclusive regarding any existing correlation between these two tests.


Introducción: La audición, sentido que nos permite recibir la información sonora, se presenta como uno de los facilitadores para una interacción social eficaz. Un déficit en esta función acarrea perjuicio en el proceso comunicativo, lo que debe ser diagnosticado y tratado lo antes posible. Actualmente disponemos de medios subjetivos y objetivos para evaluar el sistema auditivo. La audiometría tonal es la forma subjetiva más aplicada para medir ese sentido. Sin embargo, en poblaciones imposibilitadas de responder subjetivamente, se aplican técnicas subjetivas como el Potencial Evocado Auditivo de Estado Estable. Ambas investigan las respuestas auditivas del sujeto bajo test, utilizando técnicas distintas. Objetivo: Evaluar a adultos jóvenes, sin quejas auditivas, investigando la sensibilidad auditiva y, a partir de los indicadores estadísticos, calcular los promedios de la diferencias de las respuestas obtenidas en esos procedimientos, y comprobar si existe correlación entre ellos. Método: Pesquisa de respuestas auditivas vía Audiometría Tonal y Potencial Evocado Auditivo de Estado Estable en las frecuencias de 500,1000, 2000 y 4000 Hz, en 30 sujetos oyentes normales. Resultados: Tras el cálculo del promedio de las diferencias entre las frecuencias testadas en los dos procedimientos, se pudo verificar una variación de 10,47 a 18,22, donde no se ha registrado fuerte correlación en ninguna de ellas, dejando duda en la frecuencia de 1000 Hz. Conclusión: Podemos decir que los promedios de las diferencias entre los valores obtenidos en los dos procedimientos fueron razonablemente elevados, sobre todo en 500 Hz y, en menor proporción, para 4kHz. Los valores que se obtuvieron en los dos exámenes, aunque no hayan presentado fuerte correlación, se presentaron discretamente mejores para 500 Hz. Resultados de 1000 Hz no nos permiten afirmar, incluso, si hay alguna correlación entre los testes.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Audiometria de Resposta Evocada , Audiometria de Tons Puros , Limiar Auditivo , Audição , Relações Interpessoais
9.
CoDAS ; 30(4): e20170165, 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-952866

RESUMO

RESUMO Objetivo Avaliar os limiares auditivos nas altas frequências, buscando comparar as respostas entre as orelhas, verificar a correlação do nível de audibilidade com o aumento da idade e analisar as respostas por frequência para adultos normo-ouvintes. Método Este estudo foi prospectivo, quantitativo e transversal, com amostra por conveniência. Fizeram parte da amostra 60 sujeitos, com idade entre 18 e 58 anos, média de idade de 25,8 anos, com limiares auditivos dentro dos padrões de normalidade de 250 a 8000 Hz e normalidade de resultados nas medidas de imitância acústica. Para a pesquisa das altas frequências foi utilizado o equipamento de modelo AS10 HF da marca Interacoustics com fones de ouvido do tipo KOSS R/80 e com limiares expressos em dBNPS. Resultados Quanto aos limiares de audibilidade há um aumento para a orelha direita, com significância estatística em 10, 11 e 14 kHz e uma tendência à significância em 13 kHz, assim como a partir da frequência de 14 kHz há um aumento progressivo diretamente proporcional à frequência bilateralmente e quanto maior for a idade dos indivíduos, maiores serão os limiares para todas as frequências. Conclusão Os limiares de audibilidade de altas frequências tornam-se maiores com um aumento progressivo proporcional ao avanço de frequência e idade de indivíduos normo-ouvintes com valores mais elevados para a orelha direita.


ABSTRACT Purpose Evaluate high-frequency auditory thresholds, seeking to compare responses between the ears, to verify the correlation between hearing level and aging and analyze frequency responses in normal hearing adults. Methods This is a prospective, quantitative, transversal study conducted with a convenience sample. Study participants were 60 individuals aged 18 to 58 years (mean=25.82) with auditory thresholds within normality standards (250-8000 Hz) and normal results in acoustic immittance measurements. High-frequency pure-tone hearing thresholds were determined using an Interacoustics AS10HF audiometer with electrodynamic high-fidelity KOSS R/80 headphones, with thresholds expressed in dBNPS. Results Hearing thresholds showed an increase for the right ear with statistical significance at the 10, 11 and 14 kHz frequencies and a tendency to significance at 13 kHz. As of the 14 kHz frequency, a progressive increase directly proportional to the frequency was observed bilaterally, with the thresholds increasing proportionally to age advancement for all frequencies. Conclusion High-frequency auditory thresholds progressively increase proportionally to frequency and age advancement in normal hearing individuals, with higher values ​​for the right ear.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos/fisiologia , Valores de Referência , Audiometria de Tons Puros , Estudos Transversais , Estudos Prospectivos , Pessoa de Meia-Idade
10.
Braz. j. otorhinolaryngol. (Impr.) ; 83(1): 10-15, Jan.-Feb. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-839403

RESUMO

Abstract Introduction The performance of auditory steady state response (ASSR) in threshold testing when recorded ipsilaterally and contralaterally, as well as at low and high modulation frequencies (MFs), has not been systematically studied. Objective To verify the influences of mode of recording (ipsilateral vs. contralateral) and modulation frequency (40 Hz vs. 90 Hz) on ASSR thresholds. Methods Fifteen female and 14 male subjects (aged 18–30 years) with normal hearing bilaterally were studied. Narrow-band CE-chirp® stimuli (centerd at 500, 1000, 2000, and 4000 Hz) modulated at 40 and 90 Hz MFs were presented to the participants' right ear. The ASSR thresholds were then recorded at each test frequency in both ipsilateral and contralateral channels. Results Due to pronounced interaction effects between mode of recording and MF (p < 0.05 by two-way repeated measures ANOVA), mean ASSR thresholds were then compared among four conditions (ipsi-40 Hz, ipsi-90 Hz, contra-40 Hz, and contra-90 Hz) using one-way repeated measures ANOVA. At the 500 and 1000 Hz test frequencies, contra-40 Hz condition produced the lowest mean ASSR thresholds. In contrast, at high frequencies (2000 and 4000 Hz), ipsi-90 Hz condition revealed the lowest mean ASSR thresholds. At most test frequencies, contra-90 Hz produced the highest mean ASSR thresholds. Conclusions Based on the findings, the present study recommends two different protocols for an optimum threshold testing with ASSR, at least when testing young adults. This includes the use of contra-40 Hz recording mode due to its promising performance in hearing threshold estimation.


Resumo Introdução O desempenho da resposta auditiva de estado estável (RAEE) em testes de limiar com registros ipsilateral e contralateral e modulações em frequências (MFs) não tem sido sistematicamente estudado. Objetivo Verificar a influência do modo de registro (ipsilateral vs. contralateral) e da modulação em frequências (40 Hz vs. 90 Hz) nos limiares de RAEE. Método Foram estudados 15 mulheres e 14 homens (18-30 anos) com audição bilateral normal. Estímulos CE-chirp® de banda estreita (centrados em 500, 1.000, 2.000 e 4.000 Hz) modulados em 40 e 90 Hz de MF foram apresentados à orelha direita dos participantes. Em seguida, os limiares de RAEE foram registrados em cada frequência de teste nos canais ipsilateral e contralateral. Resultados Devido aos pronunciados efeitos de interação entre o modo de registro e MF (p < 0,05 por variância com dois fatores para medidas repetidas – Anova duas vias), os limiares médios de RAEE foram então comparados entre quatro condições (Ipsi-40 Hz, Ipsi-90 Hz, Contra-40 Hz e Contra-90 Hz), com o uso de variância e com um fator para medidas repetidas (Anova uma via). Nas frequências de teste de 500 e 1.000 Hz, a condição Contra-40 Hz produziu os mais baixos limiares médios de RAEE. Em contraste, em altas frequências (2.000 e 4.000 Hz), a condição Ipsi-90 Hz revelou os mais baixos limiares médios de RAEE. Na maioria das frequências de teste, a condição Contra-90 Hz produziu os mais elevados limiares médios de RAEE. Conclusões Com base nos achados do presente estudo, os autores recomendam dois protocolos diferentes para um teste de limiares ideal com RAEE, pelo menos em adultos jovens. Isso inclui o uso do modo de registro Contra-40 Hz, devido ao seu desempenho promissor nas estimativas do limiar auditivo.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Limiar Auditivo/fisiologia , Estimulação Acústica/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Valores de Referência
11.
Braz J Otorhinolaryngol ; 83(1): 10-15, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27102175

RESUMO

INTRODUCTION: The performance of auditory steady state response (ASSR) in threshold testing when recorded ipsilaterally and contralaterally, as well as at low and high modulation frequencies (MFs), has not been systematically studied. OBJECTIVE: To verify the influences of mode of recording (ipsilateral vs. contralateral) and modulation frequency (40Hz vs. 90Hz) on ASSR thresholds. METHODS: Fifteen female and 14 male subjects (aged 18-30 years) with normal hearing bilaterally were studied. Narrow-band CE-chirp® stimuli (centerd at 500, 1000, 2000, and 4000Hz) modulated at 40 and 90Hz MFs were presented to the participants' right ear. The ASSR thresholds were then recorded at each test frequency in both ipsilateral and contralateral channels. RESULTS: Due to pronounced interaction effects between mode of recording and MF (p<0.05 by two-way repeated measures ANOVA), mean ASSR thresholds were then compared among four conditions (ipsi-40Hz, ipsi-90Hz, contra-40Hz, and contra-90Hz) using one-way repeated measures ANOVA. At the 500 and 1000Hz test frequencies, contra-40Hz condition produced the lowest mean ASSR thresholds. In contrast, at high frequencies (2000 and 4000Hz), ipsi-90Hz condition revealed the lowest mean ASSR thresholds. At most test frequencies, contra-90Hz produced the highest mean ASSR thresholds. CONCLUSIONS: Based on the findings, the present study recommends two different protocols for an optimum threshold testing with ASSR, at least when testing young adults. This includes the use of contra-40Hz recording mode due to its promising performance in hearing threshold estimation.


Assuntos
Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Valores de Referência , Adulto Jovem
12.
Audiol., Commun. res ; 20(4): 305-312, out.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-770552

RESUMO

RESUMO Objetivo: Caracterizar os Potenciais Evocados Auditivos de Longa Latência (PEALL) (P1, N1, P2, N2, P300) em campo sonoro, em crianças audiologicamente normais, bem como verificar a estabilidade destes potenciais. Métodos: Trata-se de um estudo prospectivo, longitudinal, composto por 17 crianças audiologicamente normais, na faixa etária de 6 a 13 anos de idade, com limiares de audibilidade dentro da normalidade. Foram captados os PEALL P1, N1, P2, N2, P300 com estímulos de fala e tone burst, em três momentos de avaliação: avaliação inicial (M0), três meses após a avaliação inicial (M3) e nove meses após a avaliação inicial (M9). Resultados: Foi observada diminuição dos valores de latência dos componentes P1 (M0xM3 / M0xM9 / M0xM3xM9) e P2 (M0xM9) e aumento no valor de amplitude do P300 (M0xM3), quando obtidos com estímulo de fala, e diminuição no valor de latência do P300 (M0xM9), obtido com estímulo tone burst. Conclusão: Foi possível identificar os componentes do PEALL na maioria dos indivíduos. Os componentes P1, N1, P2, N2 (tone burst) e N1 e N2 (fala) não sofreram modificações em latências e amplitudes entre os diferentes momentos de avaliação, sugerindo estabilidade deste potencial no período de nove meses. O P300 demonstrou ser um componente mais sensível a esse intervalo de tempo entre as avaliações, pois sofreu modificações indicativas de maturação do sistema nervoso auditivo central. As latências de todos os componentes obtidos com estímulo de fala foram maiores do que com tone burst, demonstrando que estímulos diferentes geram respostas corticais distintas.


ABSTRACT Purpose: To characterize the Long-Latency Auditory Evoked Potentials (LLAEP) (P1, N1, P2, N2, P300) with acoustic stimuli presented in sound field system in children with normal hearing, as well as to verify the stability of these potentials. Methods: This prospective, longitudinal study comprised 17 children with ages between 6 and 13 years and hearing thresholds within normal. The LLAEP P1, N1, P2, N2, P300 were recorded with speech stimuli and tone burst presented in sound field system, in three different moments: initial assessment (M0), three months after the initial assessment (M3), and nine months after the initial assessment (M9). Results: When the speech stimuli was used, there was a decrease in the latency values of components P1 (M0xM3/M0xM9/M0xM3xM9) and P2 (M0xM9), as well as an increase in the amplitude of P300 (M0xM3) over time. With the tone bust stimuli, it was verified a decrease in the latency values of P300 (M0xM9) over time. Conclusion: it was possible to identify the components of the LLAEP in most individuals. The P1, N1, P2, N2 (tone burst) and N1 and N2 (speech) did not change their latencies and amplitudes between the different moments of evaluation, suggesting stability of this potential in the period of 9 months. The P300 was the component most sensitive to the time intervals considered, since it presented modifications over time that indicated maturation of the central auditory nervous system. The latencies of all components obtained with speech stimulus were higher than with tone bursts, indicating that different stimuli generate different cortical responses.


Assuntos
Humanos , Criança , Adolescente , Audiometria da Fala , Limiar Auditivo , Potenciais Evocados P300 , Potenciais Evocados Auditivos , Estudos Longitudinais , Estudos Prospectivos
13.
Braz. j. otorhinolaryngol. (Impr.) ; 81(6): 642-646, Nov.-Dec. 2015. tab, graf
Artigo em Português | LILACS | ID: lil-770212

RESUMO

ABSTRACT INTRODUCTION: One of the problems observed in pure-tone audiometry tonal has been the variation in test results of a same individual, particularly at frequencies of 4 kHz, 6 kHz and/or 8 kHz. Improper placement of headphones is one of the factors that can cause alterations in results. OBJECTIVE: To compare differences in auditory thresholds using earphones positioned by the examiner and by the worker. METHODS: Clinical and experimental study conducted in 2009, with 324 workers aged between 19 and 61 years, with a mean of 33.29 years and mean exposure time of 7.67 years. All subjects were familiar with audiometry procedures. Auditory thresholds were obtained at frequencies of 0.25-8 kHz, with earphones positioned by the examiners, and at frequencies of 4, 6 and 8 kHz, with earphones placed by workers in a comfortable position, following the examiner's instructions. The thresholds obtained in these two situations were compared. RESULTS: The three frequencies exhibited better responses with earphones placed by the workers themselves (p < 0.001). At a frequency of 8 kHz a greater difference was found (p < 0.001), with a mean of 13.89 dB and standard deviation of 6.07 dB. CONCLUSION: Earphone placement by the workers themselves under supervision of the examiner results in improved mean auditory thresholds at frequencies of 4, 6 and 8 kHz, the last one significantly higher than the other two.


RESUMO INTRODUÇÃO: Um dos problemas observados na audiometria tonal é a variação nos resultados de testes de um mesmo indivíduo, sobretudo nas frequências de 4, 6 e/ou 8 kHz. A colocação indevida dos fones é um dos fatores que podem causar alterações nos resultados. OBJETIVO: Comparar as diferenças nos limiares auditivos com os fones posicionados pelo examinador e pelo paciente. MÉTODO: Estudo clínico e experimental realizado, em 2009, com 324 trabalhadores, com idade entre 19 e 61 anos, média de 29,33 anos e tempo médio de exposição ao ruído de 7,67 anos; todos familiarizados com os procedimentos da audiometria. Os limiares auditivos foram obtidos nas frequências de 0,25 a 8 kHz, com os fones colocados pelos examinadores; e nas frequências de 4, 6 e 8 kHz com os fones colocados pelos trabalhadores em posição de conforto, sob orientação do examinador. Os limiares obtidos nas duas situações foram comparados. RESULTADOS: As três frequências apresentaram melhores respostas com os fones colocados pelos próprios indivíduos (p < 0,001). Na frequência de 8 kHz foi encontrada a maior diferença (p < 0,001), com média de 13,89 dB e desvio padrão de 6,07 dB. CONCLUSÃO: A colocação dos fones de ouvido pelos próprios trabalhadores, sob supervisão dos examinadores, resulta na melhora dos limiares auditivos médios nas frequências de 4, 6 e 8 kHz, sendo esta última significativamente maior que as demais.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Audiometria de Tons Puros/instrumentação , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Percepção Auditiva , Brasil , Doenças Profissionais , Saúde Ocupacional
14.
Braz J Otorhinolaryngol ; 81(6): 642-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26454532

RESUMO

INTRODUCTION: One of the problems observed in pure-tone audiometry tonal has been the variation in test results of a same individual, particularly at frequencies of 4kHz, 6kHz and/or 8kHz. Improper placement of headphones is one of the factors that can cause alterations in results. OBJECTIVE: To compare differences in auditory thresholds using earphones positioned by the examiner and by the worker. METHODS: Clinical and experimental study conducted in 2009, with 324 workers aged between 19 and 61 years, with a mean of 33.29 years and mean exposure time of 7.67 years. All subjects were familiar with audiometry procedures. Auditory thresholds were obtained at frequencies of 0.25-8kHz, with earphones positioned by the examiners, and at frequencies of 4, 6 and 8kHz, with earphones placed by workers in a comfortable position, following the examiner's instructions. The thresholds obtained in these two situations were compared. RESULTS: The three frequencies exhibited better responses with earphones placed by the workers themselves (p<0.001). At a frequency of 8kHz a greater difference was found (p<0.001), with a mean of 13.89dB and standard deviation of 6.07dB. CONCLUSION: Earphone placement by the workers themselves under supervision of the examiner results in improved mean auditory thresholds at frequencies of 4, 6 and 8kHz, the last one significantly higher than the other two.


Assuntos
Audiometria de Tons Puros/instrumentação , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Adulto , Percepção Auditiva , Brasil , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Profissionais , Saúde Ocupacional
15.
Audiol., Commun. res ; 20(3): 239-245, jul.-set. 2015. tab
Artigo em Português | LILACS | ID: lil-761559

RESUMO

Objetivo Caracterizar a variabilidade teste-reteste com fones supra-aurais e fones de inserção e comparar os limiares auditivos tonais entre os transdutores.Métodos Foram selecionados 74 indivíduos de ambos os gêneros, com limiares auditivos normais e curvas timpanométricas do tipo A. Todos os indivíduos foram submetidos à anamnese, meatoscopia, audiometria tonal por via aérea, ora com o fone supra-aural, ora com o fone de inserção, e logoaudiometria. Após esta primeira avaliação, foi realizada a medida de imitância acústica. Por fim, os procedimentos de audiometria tonal foram repetidos.Resultados O fone supra-aural produziu maior variabilidade teste-reteste, quando comparado com o fone de inserção. Já na comparação dos transdutores, verificou-se, tanto na primeira, quanto na segunda testagem, que as respostas mostraram-se ora semelhantes, ora favorecendo um ou outro transdutor.Conclusão Há maior variabilidade teste-reteste com o fone supra-aural do que com o fone de inserção. No entanto, foram verificados melhores limiares na condição reteste, para ambos os transdutores.


Purpose To characterize the test-retest variability with supra-aural and insert earphones and compare the pure tone thresholds between the transducers.Methods Seventy-four individuals of both genders with normal hearing and tympanometric curve of type A were selected. All subjects underwent anamnesis, meatoscopy, air conduction pure tone audiometry, either with the supra-aural earphone, or with insert earphone and speech audiometry. After this initial evaluation Acoustic Impedance Testswere performed. Finally, pure tone audiometry procedures were repeated with both transducers.Results Supra-aural earphone produced higher test-retest variability when compared to the insert earphones. Comparing a transducer with each other, the responses were sometimes similar and sometimes favoring one or the other transducer considering the first and second evaluations.Conclusion There is a greater test-retest variability with supra-aural earphones comparing with insert earphones. However, better thresholds were obtained in the retest condition for both transducers.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Audiometria de Tons Puros , Limiar Auditivo , Teste do Limiar de Recepção da Fala , Transdutores , Estudos Transversais , Meato Acústico Externo/diagnóstico por imagem , Anamnese , Testes de Discriminação da Fala
16.
São Paulo; s.n; 2015. [83] p. ilus, tab, graf.
Tese em Português | LILACS | ID: biblio-870749

RESUMO

INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas...


Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1,...


Assuntos
Humanos , Masculino , Feminino , Estudos de Associação Genética , Hipopituitarismo , Hormônio do Crescimento/deficiência , Hormônio do Crescimento/genética , Receptores de Fatores de Crescimento de Fibroblastos
17.
Audiol., Commun. res ; 19(3): 280-285, 09/2014. tab
Artigo em Português | LILACS | ID: lil-722598

RESUMO

Objetivo Caracterizar o sistema auditivo periférico de indivíduos com síndrome de Down, por meio da audiometria convencional e de altas frequências. Métodos Estudo do tipo transversal e observacional. Participaram 15 indivíduos com síndrome de Down, de ambos os gêneros, entre 7 e 15 anos de idade. Foram realizados os seguintes procedimentos: Meatoscopia, Timpanometria com pesquisa do reflexo acústico ipsilateral e contralateral, Audiometria Tonal, Audiometria Vocal e Audiometria de Altas Frequências. Resultados Houve predomínio de perda auditiva condutiva de grau leve, em uma ou ambas as orelhas. As médias dos limiares auditivos para a audiometria convencional ficaram abaixo de 20 dBNA e, para a audiometria de altas frequências, ficaram entre 20 e 40 dBNA. O coeficiente de correlação de Pearson revelou correlação moderada positiva, entre os limiares de 9 a 14 kHz e a idade. Conclusão De forma geral, não foram observadas diferenças significativas, quando comparadas as orelhas direita e esquerda de indivíduos com síndrome de Down, na audiometria tonal, imitanciometria e logoaudiometria. A maioria das crianças apresentou alteração de orelha média e perda auditiva condutiva. A audiometria de altas frequências sugere o início de prejuízo da função coclear, que pode estar associado às otites médias frequentes e/ou à degeneração coclear precoce. .


Purpose This study sought to characterize the peripheral auditory system of individuals with Down syndrome (DS) using conventional and high-frequency audiometry. Methods We performed a cross-sectional and observational study. Fifteen individuals with DS, who were of both genders and between 7 and 15 years of age, participated in this study. The following procedures were performed: otoscopy, tympanometry with ipsilateral and contralateral acoustic reflex, pure-tone audiometry, vocal audiometry and high-frequency audiometry. Results There was a predominance of mild conductive hearing loss in one or both ears. The mean hearing thresholds for conventional audiometry were below 20 dB HL and between 20 and 40 dB HL for high-frequency audiometry. The Pearson correlation coefficient indicated a moderate positive correlation between the 9-14 kHz thresholds and age. Conclusion Overall, no significant differences were observed when comparing the right and left ears of individuals with DS, in regards to pure-tone audiometry, immittance testing and speech audiometry. Most children showed middle ear abnormalities and conductive hearing loss. Moreover, high-frequency audiometry suggested the onset of impaired cochlear function, which may be associated with frequent otitis media episodes and/or early cochlear degeneration. .


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Síndrome de Down/complicações , Orelha Interna/lesões , Perda Auditiva/diagnóstico , Limiar Auditivo , Cóclea/anormalidades , Orelha Interna/anormalidades , Tuba Auditiva/anormalidades , Perda Auditiva Condutiva , Perda Auditiva de Alta Frequência , Perda Auditiva Neurossensorial , Hipotonia Muscular , Estudo Observacional , Otite Média com Derrame , Presbiacusia , Estudos Prospectivos
18.
Rev. CEFAC ; 15(2): 297-304, mar.-abr. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-674589

RESUMO

OBJETIVO: analisar em quanto tempo após a ativação é possível alcançar os limiares auditivos desejados nos indivíduos usuários de implante coclear (IC) multicanal de diferentes faixas etárias. MÉTODO: estudo seccional retrospectivo a partir de banco de dados, aprovado pelo CEP/HCFMUSP, sob número 779/06. Foram incluídos indivíduos implantados no período de Janeiro de 2005(início da formação do banco de dados) a Setembro de 2008(término da coleta de dados), cujos prontuários possuíam dados dos limiares audiométricos pré-implante e 3, 6 e 12 meses após o IC. Setenta e dois pacientes contemplaram os critérios, divididos em dois grupos por faixa etária: GI (até 17 anos) e GII (18 a 66 anos). Foi utilizada a Análise de Variância (ANOVA) de um fator para verificar a interação entre as médias dos limiares audiométricos e o tempo após o IC. RESULTADOS: observou-se que 15 do grupo GI já alcançaram limiares em torno de 30dBNA aos 3 meses pós implante. O mesmo aconteceu com 26 pacientes do grupo GII. Encontrou-se interação significante entre tempo (F(3,140)=91,973, p=0,00) e a média de limiares auditivos. Nas análises Post-hoc do grupo GI foram observadas diferenças estatisticamente significantes para as comparações entre AASI e 3 meses pós implante (p=0,00) e entre 3 e 12 meses (p= 0,28), para o grupo GII, somente para a comparação entre AASI e 3 meses (p=0,00). CONCLUSÃO: uma mudança significante da audição pode ser observada a partir de três meses após o IC, porém este resultado não se encontra em todos os implantados.


PURPOSE: to evaluate how long after activation one can achieve the desired auditory thresholds in individuals multichannel cochlear implant users from different age groups. METHOD: a retrospective cross-sectional from a database, approved by CEP / FMUSP, under number 779/06. Individuals implanted between January 2005 and September 2008, whose files had preoperative audiometric data and 3, 6 and 12 months after CI were included. Seventy-two patients fulfilled the criteria, and they were divided in two groups according to age: group I (17 year old) and GII (18-66 year old). Analysis of variance (ANOVA) of one factor in order to verify the interaction between the mean threshold and time after CI were used. RESULTS: we observed that 15 of the GI have reached around 30dBNA thresholds at 3 months after implant. The same happened to 26 patients of GII. We found significant interaction between time (F (3.140) = 91.973, p = 0.00) and the average hearing thresholds. Post-hoc analysis in the GI group were statistically significant differences for comparisons between HA and 3 months after implantation (p = 0.00) and between 3 and 12 months (p = 0.28). For GII only for comparison between HA and 3 months (p = 0.00). CONCLUSION: a significant hearing change may be observed beginning from three months after IC, but this result is not found in all implanted subjects.

19.
CoDAS ; 25(2): 181-187, 2013. tab
Artigo em Português | LILACS | ID: lil-678198

RESUMO

OBJETIVO: Analisar e caracterizar os limiares auditivos tonais entre 500 Hz e 16.000 Hz de músicos profissionais, integrantes de uma banda militar. MÉTODOS: Realizou-se um estudo de coorte histórico, que comparou um grupo de 50 músicos profissionais (banda militar) com um grupo sem histórico de exposição profissional a som intenso (44 sujeitos); e homogêneos (p<0,05) em relação ao gênero (masculino) e à idade (em torno de 35 anos). Foram realizados exames de audiometria tonal limiar convencional e de altas frequências (de 9.000 a 16.000 Hz). RESULTADOS: A exposição à música desencadeou alterações auditivas permanentes. Quanto aos limiares auditivos convencionais, no grupo exposto encontrou-se 32% dos músicos com alterações auditivas neurossensoriais e no grupo não exposto encontrou-se 2,27%. Os sujeitos expostos à música tiveram 14,54 vezes mais risco de adquirir alterações auditivas neurossensoriais do que o grupo não exposto. Após 20 anos de exposição à música foram observadas pioras significativas nos limiares auditivos, principalmente nas altas frequências, e ocorreram diferenças entre os grupos a partir de 30 anos de idade. CONCLUSÃO: A exposição à música desencadeou alterações auditivas permanentes, evidenciando diferenças em relação ao grupo não exposto à música, registradas na avaliação audiológica convencional e em altas frequências.


PURPOSE: To analyze and characterize tonal auditory thresholds between 500 Hz and 16,000 Hz of professional musicians, specifically members of a military band. METHODS: A historic cohort study was carried out comparing one group of 50 professional musicians (military band) with another group (44 subjects) without history of professional exposure to intense sound; the groups were homogenous (p<0.05%) in relation to gender (male) and age (about 35 years old). Tone threshold audiometry for conventional (from 500 to 8,000 Hz) and high frequencies was applied (from 9,000 to 16,000 Hz). RESULTS: Exposure to music triggered permanent hearing impairment. As to conventional auditory thresholds, the exposed and non-exposed groups presented sensorineural hearing loss of 32 and 2.27%, respectively. The subjects exposed to music had 14.54 times more risks of acquiring sensorineural hearing loss than the non-exposed group. After 20 years of exposure to music, significant worsening was observed in auditory thresholds, especially at extended high frequencies, and differences occurred between the groups from the age of 30 on. CONCLUSION: Exposure to music caused permanent hearing impairment, showing differences in relation to the non-exposed group, registered in conventional audiometry and at high-frequency audiometry.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Limiar Auditivo , Perda Auditiva Provocada por Ruído/etiologia , Música , Doenças Profissionais/diagnóstico , Exposição Ocupacional/efeitos adversos , Fatores Etários , Audiometria , Brasil , Estudos de Coortes
20.
Rev. Soc. Bras. Fonoaudiol ; 17(2): 135-141, abr.-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-639572

RESUMO

OBJETIVO: Verificar a relação entre limiares audiométricos, autopercepção do handicap e tempo para procura de tratamento em indivíduos atendidos em um serviço público de saúde auditiva. MÉTODOS: Trata-se de estudo retrospectivo, com análise de prontuários de 152 idosos e 48 adultos deficientes auditivos. As médias de limiares audiométricos ISO (500 Hz a 4 kHz) e de altas frequências (2 a 6 kHz), os limiares de reconhecimento de fala e a pontuação total e das subescalas social e emocional dos Questionários de Handicap Auditivo para Adultos (HHIA) e Idosos (HHIE) foram comparados com o tempo compreendido entre o início da queixa auditiva e o momento da procura por tratamento. RESULTADOS: O tempo médio para procura do tratamento foi de 7,6 anos. Não houve diferença entre adultos e idosos para as médias dos limiares ISO e de alta frequência, pontuação total e das subescalas do HHIA/E, e tempo para procura do tratamento. Correlações negativas fracas, porém significativas, foram observadas entre os limiares audiométricos e o tempo para procura de tratamento. Não foram encontradas relações entre o tempo para procura de tratamento e as variáveis referentes à escolaridade, nível sócio econômico e percepção do handicap. CONCLUSÃO: Os limiares audiométricos parecem influenciar a procura pelo tratamento. A despeito dos avanços tecnológicos e mudanças no acesso à informação e ao tratamento, o tempo de procura pelo tratamento é similar ao encontrado há 30 anos.


PURPOSE: To investigate the relationship between audiometric thresholds, self-perception of handicap, and time taken to seek treatment in patients treated at a public health care service. METHODS: This retrospective study analyzed the records of 152 elderly and 48 adult patients with hearing impairment. The mean ISO audiometric thresholds (500 Hz to 4 kHz) and the mean high frequencies thresholds (2 to 6 kHz), the speech recognition thresholds, and the total, social and emotional scores from the Hearing Handicap Inventory for the Adults (HHIA) and Elderly (HHIE) were compared with the time elapsed from the onset of hearing complaints and the treatment seeking. RESULTS: The mean time for seeking treatment was 7.6 years. No difference was found between adults and elderly for ISO and high frequency mean thresholds, HHIA/E scores, and time for treatment seeking. Weak but significant negative correlations were observed between auditory thresholds and time taken for treatment seeking. No relationship was found between the time taken for treatment seeking and the variables related to educational and socioeconomic levels and perception of handicap. CONCLUSION: Search for treatment seems to be influenced by auditory thresholds. Despite technological advances and changes in the access to information and treatment, the time taken for treatment seeking was similar to that reported 30 years ago.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...